Print

EUREF-Czech-2009 campaign

by Jan Douša, Vratislav Filler, Jan Kostelecký, Jakub Kostelecký, Jaroslav Šimek


This report has been submitted for evaluation by the EUREF Technical Working Group in Gaevle, Sweeden, June 1, 2010. The full report is available in the proceedings of the EUREF symposium 2010.



1 Introduction

The reasons for ETRS89 implementation in the Czech Republic were threefold:

The first expansion of the ETRS89 to the east was realized by the EUREF-CS/H’91 campaign in 1991. Eleven stations of the fundamental national geodetic network were observed by the former Institute of Applied Geodesy, Frankfurt am Main (present-day BKG) on the territories of Hungary (5 sites) and the former Czech and Slovak Federal Republic (6 sites). Only three of them (Pecný, Kleť, Přední příčka) are located on the territory of the Czech Republic and today none of them is operated as a permanent GNSS station with the exception of Pecný where the GOPE IGS/EPN station is located about 90 m apart. Note, that in processing of the EUREF-CS/H’91 campaign, which was performed in cooperation between BKG and RIGTC, no precise GPS orbits were available since it had been done in 1992 before a regular IGS operation started. Later, in 1993 the solution was slightly improved after the ideas by W. Gurtner and M. Rothacher by computing ad hoc “precise orbits” using several fiducial European permanent stations. This solution was validated by the EUREF TWG in 1994 as “class B”.


The Czech national user reference system (S-JTSK), which is one of the mandatory geodetic reference systems allowed in the Czech Republic and is used as a principal system for all legal mapping and surveying work, originates in 1927. Besides a wrong placing on the Bessel ellipsoid, wrong orientation and scale the realization of this system (first to fifth order national triangulation network) suffers from inhomogenities and many local deformations so that a large number of the triangulation points with ETRS89 coordinates regularly distributed over the entire territory is necessary to detect and rectify them. In 1992-1994, a sequence of campaigns was carried out to set up a national reference frame for the ETRS89 realization:

The above mentioned campaigns represent a hierarchy of the sequential ETRS89 densification on the territory of the Czech Republic. The national CS-NULRAD and DOPNUL campaigns, which were based on the EUREF-CS/H’91 campaign, were not submitted to the EUREF TWG for validation. None of the stations is currently operated as a permanent GNSS station.


Permanent GNSS stations in the Czech Republic Figure 1. Permanent GNSS stations in the Czech Republic

The active GNSS positioning system (CZEPOS), which was developed in the Czech Republic from 2004 to 2006, has been after an about one-year provisional operation fully operational since January 1, 2007. In 2008 and 2009, it was upgraded by implementation of the new stations, software tools and services. In April 2010, it consists of 54 permanent GPS/GNSS stations 27 of which are regularly distributed over the territory of the Czech Republic and the remaining 27 are located in the neighbour countries along the Czech border as a part of the national GNSS positioning systems of these countries. CZEPOS uses the data of these stations on the basis of bilateral agreements with their operators. Because the realization of ETRS89 coordinates in the Czech Republic comes from the early GNSS era, i.e. before the International GNSS Service (IGS) was established, the ETRS89 coordinates of CZEPOS stations were preliminary estimated from the first permanent GPS observations.


A new realization of the reference frame based on the ETRS89 coordinates of permanent GNSS stations in the Czech Republic is described in this report. This represents the first step for a further large scale densification represented by ETRS89 coordinates of about 46 500 points in the Czech Republic with an average distance of 2 km.


2 Campaign configuration

The EUREF-Czech-2009 campaign consists of available permanent GPS stations on the territory of the Czech Republic (44) and EPN stations in other European countries (18). The latter were selected using the following criteria:

EUREF permanent GNSS stations included in the campaign Figure 2. EUREF permanent GNSS stations included in the campaign

The remote stations were included to minimize possible biases on the fiducial stations and to support the estimation of absolute values of tropospheric parameters.


All Czech stations are plotted in Figure 1 and additionally introduced EPN stations in Figure 2. Only 8 from all the stations were processed for a period shorter than 3 years.


The station Sněžka (SNEC) is very well known for its problems during winter periods. The station is located on the top of the highest mountain in the Czech Republic which is well known for extremely severe weather conditions so that from early autumn till late spring its radome is usually covered with snow or, in worst case, even with a few centimetres of ice crust. The effects reached even more than decimetre in horizontal position, see e.g. EUREF CB web page coordinate time-series. For this reason, only data from snow-free periods (June-September, 2005-2009) were included in the daily processing. In 2009, the monumentation (an old building) was destroyed and the station was moved to another pillar. The reason why SNEC had to be included in the campaign was that the baselines using data from this station were observed and calculated in the past and will be probably necessary for selected local densifications.


Similar problems during winter periods can be seen in daily coordinate time-series of two other stations located at the top of high mountains in the region of Moravia – Lysá hora (LYSH) and Biskupská kupa (BISK). Nevertheless, the problems were significantly smaller and the data of winter periods were not excluded in daily processing, but only in the final combination if outliers were detected.



3 Daily processing

The processing was carried out using the Bernese GPS software V5.0 [Dach et al. 2007]. The strategy was based on the system developed at Geodetic Observatory Pecný (GOP) for the EUREF Permanent Network analysis. Only GPS data were used in the campaign, because only a few stations in the Czech Republic provide GPS+GLONASS observations and these are mostly equipped with problematic ASHTECH Z-18 receivers.


The main steps of the daily processing consist in:

  • Data and product conversion and a priori coordinates and input files preparation
  • Single point positioning based on pseudo-range observations (receiver clock synchronization)
  • Baseline definition using OBS-MAX strategy in clusters and baselines connecting the clusters
  • Triple-difference solution applied for data cleaning, cycle slip detection and ambiguity setting
  • Ambiguity-float solution for post-fit residual screening and outlier rejection
  • Iterative ambiguity-float solution for the selection of fiducial stations (datum definition)
  • Integer ambiguity resolution based on the QIF strategy
  • Ambiguity-fixed daily solution applying no-net translation (NNT) based on selected fiducial stations
  • 3.1 Processing clusters

    To complete data processing of 4 years within a few days a highly optimized processing scheme was prepared. This was achieved by splitting the network into clusters of a suitable size for parallel processing. Small clusters (4-8 stations) were designed for the ambiguity resolution and outlier rejection while large clusters (approximately 20 stations) usually for all others steps. Each processing step running in parallel ended with a combination, checking or summary extraction procedure.


    3.2 A priori coordinates

    A priori coordinates used in daily processing were prepared by merging the coordinates from three sources applied in a given order with an identification flag:

    The coordinates were expressed in the epoch of processed day according to their velocities if available.


    3.3 Orbits and Earth Rotation Parameters

    Final IGS orbits and ERPs were fixed in the daily processing. The IGS final product is based on relative models of satellite and receiver antenna phase centre variations (PCV) before GPS week 1400 and on absolute PCV models starting with GPS week 1400. The absolute models were used in the campaign processing over the whole data span whereas the most important was to apply a consistent model for both satellite and receiver antennas. The satellites with zero accuracy codes (a few cases only) were a priori excluded from the processing. Nevertheless, our procedure independently checks residuals in order to identify any problematic satellite orbits.


    3.4 Other external products and models

    Applied models were consistent with the IERS 2003 conventions:


    IGS final orbits and ERPs

    ftp://cddis.gsfc.nasa.gov/gps/products/www/igswwwd.sp3.Z

    ftp://cddis.gsfc.nasa.gov/gps/products/www/igswww7.erp.Z

    Ionospheric model

    ftp://ftp.unibe.ch/aiub/CODE/yyyy/CODwwwwd.ION.Z

    Antenna PCV

    ftp://ftp.epncb.oma.be/pub/general/epn_05.atx

    http://czepos.cuzk.cz/_paramAnten.aspx

    Ocean tide loading

    http://www.oso.chalmers.se/~loading/ (model FES2004, no CMC corrections)

    IGS05/ITRF2005

    ftp://itrf.ensg.ign.fr/pub/itrf/itrf2005/ITRF2005.SNX.gz

    ftp://igscb.jpl.nasa.gov/pub/station/coord/IGS05.snx

    EPN cumulative solution

    ftp://epncb.oma.be/epncb/station/coord/EPN/EPN_A_ITRF2005.SSC (EPN_A_ITRF2005_C1570)


    3.5 Observation sampling, weighting and elevation cut-off angle

    The 3 degree elevation cut-off angle was applied in all steps of the processing, but 10 degrees in the step for integer ambiguity resolution. By including low-elevation angle observations the estimation of horizontal troposphere gradients was supported (see Troposphere modelling). Observations with 30 sec sampling interval and the elevation dependent weighting function were used in pre-processing and 180 sec in final processing.


    3.6 Ionosphere modelling

    Wherever possible the first-order effect of the ionosphere was eliminated using ionosphere-free linear combination (single point positioning based on code observations, pre-processing for the cycle slip detection and outlier rejection and final modelling of the GPS observations for normal equation generation). The second- and third-order effects were neglected in the processing. While the estimation of the ionosphere model is also a part of our routine system, in this campaign the final CODE model was introduced to support the ambiguity resolution (see Ambiguity resolution).


    3.7 Troposphere modelling

    In pre-processing steps the troposphere effects were modelled with site-specific station parameters applying a simple tropospheric model and mapping function. In all steps requiring the highest accuracy of observation modelling, the following parameterization was applied (gradients were estimated only in the ambiguity-fixed solution):

    The troposphere parameters were pre-eliminated before saving daily normal equations. Thus, their connection at daily boundaries was not possible in the final combination. Whereas the effect on coordinate estimates in long-term combination is negligible, this approach significantly reduces requirements for the disk space and combination time.


    3.8 Data cleaning

    Detection of cycle-slips, removal of incomplete data and setting new ambiguities were done in several clusters using a triple-difference solution. Ambiguity-float solution was then used for post-fit residual screening and outlier detection. A problematic station or satellite could be detected during this step, followed by removal of all relevant data and jump back to the step of baseline definition. The last feature was practically not used in this processing campaign.


    3.9 Datum definition

    Datum realization during daily processing Figure 3. Datum realization during daily processing

    After data cleaning and outlier rejection, the daily combination of ambiguity-float solution was used for fiducial station selection. Stations used as fiducials in the IGS05 reference frame (BOR1, BRUS, GLSV, GRAS, JOZE, MATE, ONSA, POTS, WTZR, ZIMM) were used to define an initial set, while the selection procedure was based on a minimum constrained solution (NNT), which was repeated until the set of fiducial stations provided sufficiently small residuals. Only in a few cases in the whole period an additional iteration was used. The RMS of residuals for the fiducial stations were 2.4, 4.4 and 5.0 mm on average for North, East and Up, respectively. The RMS time-series are plotted in Figure 3.


    3.10 Ambiguity fixing

    Success of integer ambiguity resolution with QIF strategy Figure 4. Success of integer ambiguity resolution with QIF strategy

    The length of all baselines in the network was below 2000 km so that the QIF ambiguity resolution strategy (Mervart, 1996) could be generally applied. The ionospheric model was ready to be estimated within the campaign processing scheme, but finally this was not applied in order to minimize the time for a single day processing. The ionospheric product from the Centre of Orbit Determination in Europe (CODE) was introduced instead, which slightly increased the rate of fixed ambiguities by about 2-3% with respect to the estimated model. Apart from a priori ionosphere model, stochastic ionospheric parameters were estimated during the ambiguity fixing. The tropospheric parameters and a priori coordinates from daily ambiguity-float solution were introduced from the last iteration of the datum definition. The coordinates of one station were constrained for each cluster during the ambiguity resolution. On average 84% ambiguities were fixed. Figure 4 shows seasonal variation of the total number of fixed ambiguities per each day over the whole period.


    3.11 Daily solutions

    The final solution of daily processing consists of two steps:

    These normal equations from the network solution were input in the final 4-year combination. Nevertheless, thanks to well defined datum in daily solutions, we could directly plot daily coordinate differences with respect to simple mean values and immediately identify significant jumps and problems with daily solutions. Typical examples are given in Figure 5. Most of the coordinate differences are within ±1 cm with a standard deviation below 5 mm (including effects such as daily datum realization, antenna changes etc). All time-series are available at http://www.pecny.cz/EUREF-Czech-2009/DAILY-TIMESERIES.




    4 Final combination

    The Bernese ADDNEQ2 program was used for the final combination based on stacking daily normal equations (NEQ). Although the network spread over a stable part of Europe, coordinates and velocities were introduced as unknown parameters for this campaign covering the period of 4 years. The combination step consists in the identification of outliers and jumps, selection of fiducial stations and in setting pre-defined intervals for coordinate and velocity estimation. More different combination variants have been computed in order to achieve the best results. Because we introduced 24 EPN stations of Class A (6 in the Czech Republic and 18 external) in daily solutions, we didn’t need to combine NEQs with EPN weekly solutions. This was confirmed by a stable realization of the IGS05 reference frame on a daily basis, which was visualized in the preliminary time-series of coordinate differences with respect to a simple mean from independent days, see http://www.pecny.cz/EUREF-Czech-2009/DAILY-TIMESERIES.


    .


    4.1 Fiducial stations

    Sufficient number of EPN Class A station candidates was available for the campaign and the selection of the most reliable set resulted in these different variants (full station lists are given in Table 3):


    4.2 Reference coordinates and velocities

    The coordinates and velocities from the EPN cumulative solution EPN_A_ITRF2005_C1570 were used as a reference for all fiducial stations. During the campaign period, several sets of coordinates were published for most of the stations included in the campaign. These are usually related to the change of antenna or receiver. However, there are many coordinate changes at GPS week 1400, which are related to the changes in the EPN processing strategy – the most important was a switch from the relative to absolute phase centre model. For many stations, this caused a station-specific change in coordinates at a level of millimetres for horizontal position and centimetres in height.


    The campaign covered the period both before and after GPS week 1400, while the absolute phase centre variation model was applied for the whole campaign processing period. Since the coordinates in the EPN cumulative solution before GPS week 1400 are based only on the processing that use relative phase centre variation model, we clearly identified jumps in our preliminary coordinates induced by this model change. These artificial jumps were eliminated in our campaign by omitting those sets of EPN coordinates with a time span limited only to a period before GPS week 1400. Instead, the coordinates starting at GPS week 1400 were used also for such station for the period without any instrumentation change. A consistency of the coordinates was thus guaranteed as long as possible also before GPS week 1400 and reference coordinates from the old model were used only in a few short periods at the beginning for these stations – DRES, GOPE, PENC, RIGA, TUBO and WROC.


    A priori coordinates of all non-EUREF campaign stations could be set up at a decimetre level. Since the campaign covered 4-year period and the processing has been done in a global reference frame, velocities should be estimated as well. For a few stations we tightly constrained these velocities to their a priori values (because of short-time observed period), therefore we set their a priori velocities consistently with the rotation of ETRF2000 with respect to ITRF2005.


    4.3 Outlier rejection

    The final combination was done in an iterative way in order to eliminate outliers. The following criteria were used for the outlier detection:

    The number of excluded days in final combination due to these criteria was 182 and 62 on fiducial and other stations, respectively.


    Table 1. Periods of manually data exclusion because of a priori known problems
    Site From To Length (days) Problem
    JOZE2005 12 012006 02 28424 systematic outliers
    BISK2005 11 202006 03 10110 winter outliers
    BISK2007 12 122007 12 2312 series of Up outliers
    LYSH2005 10 152005 10 2511 winter 2005/6, part 1
    LYSH2005 11 012006 04 15165 winter 2005/6, part 2
    LYSH2006 10 152007 03 20156 winter 2006/7
    LYSH2007 10 102008 02 20133 winter 2007/8
    SNECOct- -May ~60%all winter periods excluded in daily solutions
    KUNZ2006 01 012006 03 0766 winter 2005/6

    4.4 Coordinate and velocity estimation

    The coordinates of all stations were estimated in pre-defined intervals according to the jumps identified from residual time-series. Sets of fiducial stations were used for the datum definition using the minimum constrained solution (no-net translation). The velocities were estimated only for all non-EUREF stations observed over 3 years. Since a priori velocities for such stations originated from a common ETRF2000 trend, we estimated corrections only and whenever more intervals for station coordinates were pre-defined, these corrections were estimated uniquely over the whole interval (there was no reason for splitting velocities during the campaign period).


    In variants A, B and C, we have estimated only horizontal velocities in all variants, while vertical velocities were tightly constrained to their a priori values. In variant D, vertical velocities were also estimated for all stations observed over more than 3 years. The reference velocities of all EPN stations were always tightly constrained since we assumed that they could not be estimated with a higher quality than in the EPN cumulative solution.




    5 Campaign Results

    Table 2. Translations and RMS errors with respect to the EPN cumulative solution
    Variant

    Translations [mm]

    (all "Class A" sites)

    Translations [mm]

    (selected fiducal sites only)

    RMS [mm] of Helmert transformation

    (selected fiducal sites only)

    NorthEastUpNorthEast UpNorthEastUpTotal
    A-0.0-0.9-0.5+0.1-0.1-0.01.00.83.52.1
    B-0.0-0.9-0.6+0.1-0.1-0.01.00.83.62.2
    C+0.3-0.1-0.9+0.1-0.1-0.11.12.13.22.3
    D+0.4-0.4-1.3+0.1-0.1-0.01.11.22.51.7

    Coordinate residuals at fiducial EPN stations (red) for D variant (non-fiducial EPN stations are plotted with pink). Figure 5. Coordinate residuals at fiducial EPN stations (red) for D variant (non-fiducial EPN stations are plotted with pink).

    3D Helmert transformation (translation estimates) was performed for all the combination variants in order to assess the closeness of resulting coordinates to the ETRS89 realization (EPN cumulative product). The estimated translations for each variant using all class ‘A’ stations are within 1.3 mm in East, North and Up component, see Table 2. This result proved that any selection of ten or more fiducial stations in the campaign is reliable for the realization of the ETRS89 reference system at a millimetre level.


    Estimated corrections (variant D) for non-EUREF stations (pink points) to the common ETRF2000 velocity field.
For all EPN stations (red points) velocities were constrained to the EPN cumulative solution. Figure 6. Estimated corrections (variant D) for non-EUREF stations (pink points) to the common ETRF2000 velocity field. For all EPN stations (red points) velocities were constrained to the EPN cumulative solution.

    The table further shows fulfilled NNT conditions and RMS from coordinate residuals of applied fiducial stations. The solution ‘D’ shows clearly a superior performance while total RMS of Helmert transformation decreased to 1.7 mm. The solution ‘D’ was selected as final also because it includes as many as fiducial stations and excluding only three stations (MATE, and partly GOPE, WROC) with residuals larger than 6 mm in any component. Besides the station selection, Table 3 summarizes residuals from the final solution D and Figure 6 plots their geographical distribution.


    North, East and Up repeatabilities for all stations from the final combination (D variant). Figure 7. North, East and Up repeatabilities for all stations from the final combination (D variant).

    Estimated coordinates and velocities in ITRF2005 and ETRF2000 reference frames are summarized in Appendix. Figure 5 visualizes velocity corrections from the final solution (D) with respect to a priori velocities. Velocity differences are very small (bellow 1mm/year) for all stations, but for SNEC and CPRA.


    Repeatabilities for all stations were calculated for each variant, but they do not differ significantly – 2mm in horizontal component (only SNEC slightly more) and usually 4 mm in vertical (with a few stations up to 6 mm). Figure 7 shows repeatabilities for final solution (D).


    The examples of coordinate time-series from the final combination are given in Figure 9 for three stations – one fiducial (POTS) and two CZEPOS stations (CPAR, CJIH). While CPAR is an example of an excellent performance, CJIH suffers from a seasonal effect probably due to steel mast monumentation. A similar but smaller effect was detected at some other CZEPOS stations with the same type. The time-series of all other stations can be found at http://www.pecny.cz/EUREF-Czech-2009/FINAL-TIMESERIES.


    Table 3. Selection of fiducial stations for different variants. Residuals from Helmert transformation between final variant D and EPN cumulative solution. Stations with flag M were only compared in the transformation.
    Station Fiducial set D - final solution
    A B C D North [mm] East [mm] Up [mm] Flag
    BISK 11520M001 x x 0.2 0.8 0.6
    BOR1 12205M002B x x x x -0.3 -0.5 0.4
    BRUS 13101M004B x x x x -0.7 1.7 -1.2
    DRES 14108M001 x x -1.3 -2.1 -2.3
    DRES 14108M001C x x -1.2 -1.7 -1.3
    DRES 14108M001D x 2.2 0.0 6.7 M
    GLSV 12356M001B x x x x 2.3 -0.3 2.5
    GLSV 12356M001C x x x x 1.2 0.0 3.6
    GOPE 11502M002 3.2 -1.4 -17.2 M
    GOPE 11502M002B 2.7 -1.1 -20.3 M
    GOPE 11502M002C x x 0.1 0.1 0.7
    GRAS 10002M006B x x x x 0.2 1.3 -4.1
    GRAZ 11001M002 x x 0.3 0.1 -1.1
    GRAZ 11001M002B x x -0.7 -2.1 -2.5
    GRAZ 11001M002D x x 0.0 1.0 -1.5
    JOZE 12204M001B x x x x 0.0 -0.2 1.3
    LINZ 11033S001B x x 0.1 1.0 -2.0
    MARJ 11517M001B x x 0.2 1.0 0.4
    MATE 12734M008B x x x 2.4 0.8 -6.5 M
    MATE 12734M008C x x x 0.4 1.5 -7.1 M
    MOPI 11507M001B x x 0.1 0.3 -1.9
    ONSA 10402M004B x x x x -0.7 -0.1 2.8
    PENC 11206M006 x x -3.6 -0.2 -0.2
    PENC 11206M006B x x 0.2 0.4 1.7
    PENC 11206M006C x x 3.0 -2.3 -1.9
    POTS 14106M003 x x x x -0.3 0.3 2.3
    POUS 11518M001 x x -0.1 1.2 0.1
    RIGA 12302M002 x x -0.4 -1.0 1.9
    RIGA 12302M002B x x -0.6 -1.0 2.5
    RIGA 12302M002C x x 0.3 -0.6 4.6
    SOFI 11101M002 x x x 0.4 0.3 -1.5
    TUBO 11503M001 x x -0.8 -2.1 -2.7
    TUBO 11503M001B x x 1.4 3.0 -5.7
    TUBO 11503M001D x x -0.3 -1.0 4.6
    VACO 11516M001B x x 0.7 0.4 1.5
    WROC 12217M001 x 0.3 -0.5 -6.3 M
    WROC 12217M001C -0.8 -10.9 -0.9 M
    WROC 12217M001D x x -0.2 -0.4 0.7
    WTZR 14201M010B x x x x 0.3 1.1 1.3
    ZIMM 14001M004B x x x x 0.2 0.7 -3.8
    RMS / comp. x 1.1 1.2 2.5
    Translations x 0.1 -0.1 0.0



    6 Transformation to ETRS89

    The final combination was calculated in the International Terrestrial Reference System (ITRS), which requires velocities to express coordinates in different epochs. Resulting coordinates from our combination had to be transformed into the European Terrestrial Reference System (ETRS89) in order to minimize coordinate changes in time. The latest ETRS89 realization based on ITRF2005 is maintained via the cumulative EPN solution (Kenyeres, 2009).


    In transformation we followed the procedure described in Memo (Boucher and Altamimi, 2008) using two approaches to transform ITRF2005 coordinates and velocities into the ETRF2000:

    Both transformations approaches agrees on submilimetre level and the difference is caused by rounding errors when reproducing coefficients directly from the Memo. The coefficients are more accurately given at http://itrf.ensg.ign.fr/ITRF_solutions/2005/tp_05-00.php. The EPN web-page service (http://epncb.oma.be/_dataproducts/coord_trans), which are using those more accurate coefficients, was finally used in the transformation.




    7 Comparison with previous realization

    This comparison evaluates the quality of older campaigns that contributed to the previous ETRS89 realisations in the Czech Republic than the quality of this campaign. However it is important to consider the discontinuity between previous and current national ETRS89 realisations.


    The previous realisation of ETRS89 is described in Section 1. As a result, there exists a set of ETRS89 coordinates for 27 actually processed sites of the CZEPOS network in previous realisation. Table 9 shows translations and RMS errors estimated from Helmert transformation.


    Nearly 1 cm offset in the North component is remarkable. Except that, the comparison shows a good agreement on a centimetre level in horizontal direction and a few centimetres in height. Only one station (CPRA) shows more than 15 mm difference in horizontal direction and two stations (CPRG and CMBO) exceed 30 mm in vertical direction.


    Tab 9. Translations and RMS errors from Helmert transformations with respect to the previous ETRS89 realisation
    Number of sites Translations RMS of Helmert transformation
    North [mm] East [mm] Up [mm] North [mm] East [mm] Up [mm] Total [mm]
    27 9.9 -1.7 1.1 5.3 6.5 15.6 10.2


    8 Conclusions

    Altogether 44 Czech national and 18 EPN stations located in other European countries were processed during 4-year campaign and combined coordinates were converted into ETRF2000. For most of the stations 4-year observation time-series were considered, for some shorter time series, but minimally of 1 year. Data from winter periods were excluded for SNEC and LYSH stations located on the top of high mountains.


    A high internal consistency of the campaign solution during the whole period is demonstrated by daily coordinate repeatabilities for all stations with a maximum of 2, 2 and 6 mm in North, East and Up component, respectively.


    Four variants were tested differing in fiducial station configuration and coordinate and velocities parameterization. No significant difference between the realizations of the ETRS89 was found since all of them agreed within 1.3 mm in three translations.


    Finally, 23 fiducial stations were selected for the final realization using a minimum constrained solution (no-net translation) with respect to the EPN cumulative solution (EPN_A_ITRF2005_C1570). Residuals on the fiducial stations demonstrate the consistency of estimated coordinates with ETRS89 at the level of 1.7 mm in total RMS from Helmert transformation and 1.1, 1.2 and 2.5 mm for North, East and Up component, respectively.


    An indirect comparison with the previous ETRS89 realization in the Czech Republic could only be applied using coordinates derived in roundabout multi-step approach for all CZEPOS stations (see description of previous realization of ETRS in the Czech Republic in Section 1). The total RMS from the Helmert transformation for 27 stations is 10.2 mm (in 2007.0), while estimated translation parameters were 9.9, -1.7 and 1.1 mm for North, East and Up components, respectively.


    The EUREF Technical Working Group was asked to validate the coordinates (not velocities) resulting from this campaign. The campaign was validated at the EUREF TWG meeting on June 1st, 2010, in Gaevle, Sweeden, which was confirmed by resolution No. 1 from the EUREF Symposium 2010 at the same place.




    Ackwnoledgements

    The data and products used in the EUREF-Czech-2009 campaign processing were kindly provided by the following organizations:


    All these contributions are gratefully acknowledged.




    References